 12. If the engine does not start, repeat STEPS 5 - 8
and try again. If it still does not start, check the
spark plug gap (0.020mm). Because it has an
electronic ignition, there are no points to gap.
 13. As the engine warms up, slowly move the choke
lever to the "RUN" position (lever up).
OPERATING PROCEDURES: MIST SPRAY AND ULV
 14. a. Set the engine throttle at half speed, and after the
engine is operating smoothly, open up the inline
flow valve (mist spray and large ULV operations),
and the volume control cock.
 b. Calibrate the system (The liquid must pass
through the metering system and must be
separate from the air flow).
 c. For adjusting the liquid flow rate to the label and
application specifications, use the volume control
cock (mist spray) or slide bar (ULV).
DUSTS AND GRANULES
 15. a. Set the engine throttle halfway and after the
engine is running smoothly, twist the plastic
discharge tubing where the pesticide feed hose
connects to it. (With the engine set at half throttle
and the pesticide discharge tube open all the
way; the unit will put out approximately 5 kg/min).