15. Air pressure to the spray head should be 60-90 psi
as indicated by the green area of the air pressure
gauge.
FLOW RATES
16. Rate of formulation is controlled by a metering orifice
located in the fitting at the top of the formulation
tank. Additional fittings are located in a small
compartment on the base of the frame behind the
formulation tank.
17. Orifice disk system-The orifice disc should be placed
inside the filter/orifice chamber, which is located in
the outlet of the formulation tank.
18. To remove or change an orifice disc, first use (2)
13
/
16
” wrenches (one to hold the tank fitting, and the
other to unscrew filter/orifice chamber nut) then
remove nut and fluid line, then hold the smaller hex
nut using a wrench and loosen the hex retainer nut
and another 13/16” wrench to hold the tank fitting.
19. Using a smaller orifice size will reduce the
formulation flow rate and using larger orifice size
will increase the formulation flow rate.
CALIBRATION
20. Since the nozzle used is an external mix siphon
(suction) type nozzle, calibration must be made with
the machine running.