135
33. Place the Output Switch on the Remote Control in
the “ON” position (fluid will begin to flow).
34. Adjust the Flow Rate Knob on the Remote Control
Box to the desired rate.
35. The timing person signals the beginning and the
end of the one (1) minute collection period.
36. Collect sample and compare actual output with
desired output indicated by Remote Control Box
digital read-out.
37. If sample is NOT within 20% of the volume given
by the Remote Control Box digital read-out, contact
manufacturer or NDVECC, Bangor.
TERMINATING PROCEDURES
38. After flushing entire system, wash or steam clean
outside of ULV machine with liquid soap and water.
Note: get no water on Remote Control Box.
39. Break connection at Fuel Tank/Fuel Line junction
and restart Engine to drain the Carburetor prior to
storage.
40. Keep sprayer under suitable cover and out of
weather.