 33. Place the Output Switch on the Remote Control in
the “ON” position (fluid will begin to flow).
 34. Adjust the Flow Rate Knob on the Remote Control
Box to the desired rate.
 35. The timing person signals the beginning and the
end of the one (1) minute collection period.
 36. Collect sample and compare actual output with
desired output indicated by Remote Control Box
digital read-out.
 37. If sample is NOT within 20% of the volume given
by the Remote Control Box digital read-out, contact
manufacturer or NDVECC, Bangor.
TERMINATING PROCEDURES
 38. After flushing entire system, wash or steam clean
outside of ULV machine with liquid soap and water.
Note: get no water on Remote Control Box.
 39. Break connection at Fuel Tank/Fuel Line junction
and restart Engine to drain the Carburetor prior to
storage.
 40. Keep sprayer under suitable cover and out of
weather.